What Size Air Conditioner Do I Need?
A 150 sq ft bedroom needs a 5,000 BTU unit, a 400 sq ft living room about 8,000 BTU, and 1,000 sq ft about 20,000 BTU — 2 tons — before climate and insulation adjustments.
Checked and reviewed by Zia ur Rehman, site owner · Last reviewed: November 2026 · The formula is shown on this page and the sources behind the numbers are listed at the foot of the page.
The short answer: 20 BTU per square foot, then adjust — and buy the nearest size up
Air conditioners are sized in BTU per hour — the amount of heat the unit can remove in an hour. The long-standing rule of thumb, and the starting point of the US Department of Energy's guidance, is 20 BTU per square foot for a room with 8 ft ceilings in a moderate climate with average insulation. A 150 sq ft bedroom starts at 3,000 BTU; a 400 sq ft living room at 8,000 BTU; 1,000 sq ft at 20,000 BTU. Then you adjust for your climate, insulation, sun, ceiling height and who uses the room — and buy the nearest standard unit size at or just above the result. Central systems use tons instead of BTU: 1 ton = 12,000 BTU.
Use the BTU Calculator for the exact figure on your room — every number on this page matches it. The chart below is the quick version, for a moderate climate with average insulation and 8 ft ceilings; the worked examples show how the adjustments move the answer.
Room size to BTU chart
| Room size (sq ft) | BTU needed | Tons | Typical equipment |
|---|---|---|---|
| 100–150 | 5,000 | — | Small window AC |
| 150–250 | 6,000 | 0.50 | Window AC |
| 250–300 | 7,000 | — | Window AC |
| 300–350 | 8,000 | — | Window AC |
| 350–400 | 9,000 | — | Window AC |
| 400–450 | 10,000 | — | Window AC |
| 450–550 | 12,000 | 1 | Large window AC / mini-split |
| 550–700 | 14,000 | — | Mini-split |
| 700–1,000 | 18,000 | 1.5 | Mini-split |
| 1,000–1,200 | 21,000 | — | Mini-split |
| 1,200–1,400 | 23,000 | — | Mini-split |
| 1,400–1,500 | 24,000 | 2 | Mini-split / small central |
The chart is a starting point, not a shopping list: a sunny room in a hot climate can need a full size more than the chart says, and a shaded, well-insulated room can need a size less. The adjustments below are how you move from the chart to your room.
The formula, and every adjustment
The BTU Calculator starts from 20 BTU per square foot and applies these multipliers, then adds flat amounts for people and kitchens:
| Adjustment | Factor | What it means |
|---|---|---|
| Climate — cool (northern / coastal) | × 0.90 | Mild summers: Chicago, Seattle, San Francisco. |
| Climate — moderate | × 1.00 | The baseline: Nashville, Kansas City, Denver. |
| Climate — warm | × 1.10 | Long hot summers: Houston, Atlanta, Sacramento. |
| Climate — hot | × 1.25 | Desert Southwest and deep South: Phoenix, Las Vegas, Miami. |
| Insulation — good | × 0.90 | Newer home, sealed and well insulated. |
| Insulation — average | × 1.00 | The baseline. |
| Insulation — poor | × 1.20 | Older, drafty home. |
| Sun — shaded | × 0.90 | Little direct sun on the windows. |
| Sun — average | × 1.00 | The baseline. |
| Sun — sunny | × 1.10 | Big south- or west-facing windows. |
| Ceiling height | + 5% per foot above 8 ft | A 10 ft ceiling adds 10%; a 12 ft vaulted ceiling adds 20%. |
| Windows — few or small | × 0.95 | Small windows, little glass. |
| Windows — many or large | × 1.10 | A wall of glass. |
| People | + 600 BTU each beyond 2 | Each extra regular occupant adds body heat. |
| Kitchen | + 4,000 BTU | Cooking heat — a range and oven pour thousands of BTU an hour into the room. |
Climate is the biggest single adjustment: the same 300 sq ft room needs 5,400 BTU on the cool setting and 7,500 BTU on the hot setting before anything else changes — a full unit size apart. If your town sits between two climate rows, pick the higher one for a west-facing or top-floor room and the lower one for a shaded ground-floor room.
Worked examples
A 150 sq ft bedroom. 150 × 20 = 3,000 BTU at the baseline. The smallest common window unit is 5,000 BTU, so buy a 5,000 BTU unit — it is already oversized for the room on paper, which is fine at this size: a 5,000 BTU unit in a 150 sq ft room cycles a little more but the room is small enough that humidity is not a problem, and there is nothing smaller to buy. If the bedroom is hot, sunny and poorly insulated, the figure rises to 3,000 × 1.25 × 1.1 × 1.2 = 4,950 BTU — still a 5,000 BTU unit.
A 400 sq ft living room. 400 × 20 = 8,000 BTU at the baseline, so buy an 8,000 BTU unit. With a sunny western exposure in a warm climate the figure becomes 8,000 × 1.1 × 1.1 = 9,680 BTU, so buy a 10,000 BTU unit — the chart's 400–450 sq ft row already points at 10,000 BTU, because real living rooms usually carry at least one of these adjustments.
A 300 sq ft room in the worst combination. Baseline 6,000 BTU. Hot climate (× 1.25), sunny (× 1.1), poor insulation (× 1.2) and a 10 ft ceiling (+10%): 6,000 × 1.25 × 1.1 × 1.2 × 1.10 = 10,890 BTU, so buy a 12,000 BTU unit (1 ton). The same room in a cool, shaded, well-insulated house needs only 6,000 × 0.9 × 0.9 × 0.9 = 4,374 BTU — a 5,000 BTU unit. Same tape measure, two sizes apart: this is why a bare square-footage chart undersizes exactly the rooms that are hardest to keep comfortable.
1,000 sq ft of open-plan living space. 1,000 × 20 = 20,000 BTU at the baseline — 1.67 tons. In a mild, well-insulated space the nearest standard size is an 18,000 BTU (1.5 ton) mini-split. Poor insulation alone pushes it to 20,000 × 1.2 = 24,000 BTU, a 2 ton unit; hot climate and poor insulation together push it to 20,000 × 1.25 × 1.2 = 30,000 BTU, a 2.5 ton unit. One open-plan space can take a single large head; the same area split into bedrooms usually does better as a multi-zone system with a smaller head per room.
A 200 sq ft kitchen. Baseline 200 × 20 = 4,000 BTU, plus 4,000 BTU for cooking heat = 8,000 BTU, so buy an 8,000 BTU unit. For a kitchen that is rarely cooked in, the lower end of the usual 1,200–4,000 BTU cooking range is fine — but a heavily used kitchen is the one room where undersizing shows up fastest, on the hottest evening of the year, with the oven on.
A 250 sq ft home theater with four people. Baseline 250 × 20 = 5,000 BTU, plus 600 BTU for each of the two extra occupants = 5,000 + 1,200 = 6,200 BTU, so buy a 7,000 BTU unit — the nearest standard size at or above the result. The people adjustment matters most in theaters, offices and party spaces: a six-person room gains 2,400 BTU, which can be a full unit size.
Tons, converted
Window units and mini-splits are sold in BTU; central systems are sold in tons. The conversion is exact — 1 ton = 12,000 BTU per hour, from the amount of cooling produced by melting a ton of ice over 24 hours:
| Tons | 0.5 | 1 | 1.5 | 2 | 2.5 | 3 | 3.5 | 4 | 5 |
|---|---|---|---|---|---|---|---|---|---|
| BTU/hr | 6,000 | 12,000 | 18,000 | 24,000 | 30,000 | 36,000 | 42,000 | 48,000 | 60,000 |
A typical whole house uses 2–5 tons of central cooling. When comparing quotes, convert everything to the same unit: a 2.5-ton central system and a 30,000 BTU mini-split are the same capacity.
Why oversizing hurts: short-cycling and humidity
Buying bigger "to be safe" is the most common sizing mistake, and it makes the room less comfortable, not more. An oversized unit cools the air in a few minutes and shuts off — before it has run long enough to pull the humidity out of the air. The result is a room that feels cold and clammy at the same time, with temperatures swinging between cycles, the compressor wearing from constant starting, and a higher electricity bill for worse comfort. A correctly sized unit runs long, steady cycles through the hottest part of the day, which dehumidifies properly and usually costs less to run.
Undersizing is the failure people expect: on the hottest afternoons the unit runs flat out and the room still sits a few degrees above the thermostat setting. But a slightly undersized unit is only a problem on those peak days — for the other 95% of the season it runs long, steady cycles, dehumidifies well and costs less. That is why the advice on this page is always the nearest size at or just above the calculation — never a full size up "to be safe."
Window AC, mini-split or central?
Window AC fits rooms up to about 550 sq ft (up to 14,000 BTU): cheap to buy, easy to install, and the right answer for one room. Ductless mini-splits cover roughly 14,000–36,000 BTU and suit larger rooms, open-plan spaces and multi-zone setups — quieter and more efficient than window units, at a higher installed cost. Central air is the answer for a whole house: 2–5 tons, ducted, and sized by a professional load calculation (see below), not by this page's rule of thumb.
This is not a Manual J calculation
Professionals sizing a whole-house system use Manual J, the ACCA load-calculation standard, and it is a different class of tool from this page. A Manual J works room by room with your actual construction: wall and ceiling insulation values, window sizes, orientations and U-factors, measured air leakage, duct losses, local design temperatures and the internal heat from people and appliances. It commonly lands 20–40% below rule-of-thumb figures for whole houses, because the 20 BTU per sq ft shortcut quietly assumes older, leakier construction.
For a single window unit or a one-room mini-split, this page's estimate is the right level of effort — the cost of being one size off is small. For a central system or a whole-house mini-split installation, ask the installer for the Manual J summary behind their quote (reputable installers run one as part of the job; a standalone calculation typically runs a few hundred dollars, US, as a rough range). A contractor who sizes a whole house from square footage alone is guessing with your money.
Common mistakes
- Buying a size up "to be safe." An oversized unit short-cycles, leaves the room clammy, and wears the compressor. Buy the nearest standard size at or just above the calculated figure — not a full size up.
- Sizing from square footage alone. A 300 sq ft room ranges from 4,374 to 10,890 BTU depending on climate, sun, insulation and ceiling height. Use the calculator with your actual conditions, not the chart alone.
- Forgetting the ceiling height. The 20 BTU baseline assumes 8 ft ceilings. A 12 ft vaulted ceiling adds 20% — a 300 sq ft room goes from 6,000 to 7,200 BTU before any other adjustment.
- Sizing one room when two share an open doorway. If two rooms share an open doorway and one unit must cool both, add their areas together and calculate once — a unit sized for one room will lose the fight against the combined space.
- Ignoring the kitchen's cooking heat. A kitchen needs 4,000 BTU on top of its room figure. Sizing a kitchen like a bedroom guarantees the hottest room in the house on the hottest evening of the year.
- Trusting the box's square-foot claim. The square footage printed on a unit's box assumes moderate conditions. In a hot climate or a poorly insulated space the effective coverage falls by a quarter or more — run the numbers for your room instead.
Frequently Asked Questions
What size air conditioner do I need for a 150 sq ft bedroom?
About 5,000 BTU. The baseline is 150 × 20 = 3,000 BTU, but 5,000 BTU is the smallest common window unit size, so that is what you buy. Even in a hot, sunny, poorly insulated bedroom the figure only rises to about 4,950 BTU — still a 5,000 BTU unit.
How many BTU do I need for a 400 sq ft room?
About 8,000 BTU at the baseline (400 × 20). Buy an 8,000 BTU unit for a moderate, average room; with a sunny western exposure in a warm climate the figure rises to about 9,680 BTU, so buy a 10,000 BTU unit.
How many BTU is one ton of air conditioning?
One ton equals 12,000 BTU per hour. Central systems are labelled in tons (a typical house uses 2–5 tons) while window units and mini-splits use BTU directly, so converting matters when comparing quotes: a 2.5-ton central system and a 30,000 BTU mini-split are the same capacity.
Is a bigger air conditioner better?
No — oversizing is a real problem, not a luxury. An oversized unit cools the air quickly and shuts off before it has run long enough to remove humidity, so the room feels cold and clammy, temperatures swing, and the frequent start-stop cycling wears the compressor and wastes electricity. Buy the nearest size at or just above the calculation.
What size mini-split do I need for 1,000 square feet?
At 20 BTU per square foot, 1,000 sq ft starts at 20,000 BTU, so the nearest standard sizes are 18,000 BTU (1.5 ton) in a mild, well-insulated space or 24,000 BTU (2 ton) with poor insulation — 30,000 BTU (2.5 ton) if the climate is hot as well. Open-plan spaces can use a single head; the same area split into bedrooms usually does better with a multi-zone system.
Sources and Method
The constants and rules of thumb on this page come from the published references below. Where a figure is a range, the calculator uses the mid-range value and the text says so.
- ACCA Manual J — the professional residential heating and cooling load calculation this quick estimate does not replace.
- US Department of Energy, Energy Saver — room air conditioner sizing guidance (about 20 BTU per sq ft as a starting point, 600 BTU per extra occupant, 4,000 BTU for a kitchen).